Study on the Relationship between Aspects, Orientation,Type, and Unit Position toward to Indoor Air Quality in Flat
View/ Open
Date
2013-05Author
Tobing, Rumiati R.
Karyono, Tri Harso
Sabaruddin, Arief
Metadata
Show full item recordAbstract
Thermal factor is one of the main factors of the green building concept. The purpose of this research is to test building
performance through design aspect that influences thermal comfort, the design aspects include: orientation, building
type, and position of the flat. Method used in this research is covariance analysis, testing the influence of factor variable
toward respond variable (indoor temperature) with taking outdoor temperature as concomitant variable. The cases tested
on this research are Cigugur Tengah, Industri Dalam, and Sarijadi flats. Result of covariance analysis shows that the
building orientation factor variable is most influentially variable toward thermal comfort, compared with building type
factor variable; even the unit position factor variable has no significant influence toward thermal comfort.